Thoát nước, Nước thải & Thông hơiCâu 62 / 360
A 4 inch building drain must be installed at a minimum slope of:
a.1/4 inch per foot
b.1/8 inch per foot
c.1/16 inch per foot
d.3/16 inch per foot
Giải thích
For drainage pipe 3 inches and larger, the CPC permits a minimum slope of 1/8 inch per foot (about 1 percent). The 1/4 inch per foot minimum applies to pipe 2-1/2 inches and smaller. The 1/16 and 3/16 inch values are not code minimums for a 4 inch drain.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §708.1Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- What is the minimum slope for a 2 inch horizontal drainage pipe?
- Each fixture trap must have a water seal with a depth of not less than and not more than:
- For a 1-1/2 inch trap arm, the maximum developed length from the trap weir to the vent is:
- Cleanouts in horizontal drainage lines must be spaced no more than:
- The minimum diameter of a vent pipe must be:
- What is the minimum clearance required in front of a cleanout on a 4 inch drainage pipe?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra