Thoát nước, Nước thải & Thông hơiCâu 63 / 360
Each fixture trap must have a water seal with a depth of not less than and not more than:
a.1 to 2 inches
b.1-1/2 to 3 inches
c.2 to 4 inches
d.3 to 5 inches
Giải thích
The CPC requires each trap to have a liquid seal of not less than 2 inches and not more than 4 inches, except for special deep-seal traps. A shallower seal is easily lost to evaporation or siphonage, and a deeper seal beyond code is only allowed for approved deep-seal designs. The other ranges fall outside the required 2 to 4 inch window.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §1002.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.