Recovery & RecyclingCâu 208 / 240
Recovered refrigerant must be stored in:
a.A disposable one-trip cylinder
b.Any empty refrigerant drum
c.An open container in a ventilated room
d.A DOT-approved refillable recovery cylinder
Giải thích
Recovered refrigerant must go into a DOT-approved refillable recovery cylinder, never a disposable one-trip cylinder, which is illegal and unsafe to refill. The cylinder must be within its hydrostatic test date and filled to no more than 80 percent. Proper cylinders prevent contamination and rupture.
Trích dẫn luật: 40 CFR §82.154Luyện miễn phí toàn bộ 240 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Recovery equipment manufactured on or after November 15, 1993 must be:
- Self-contained (active) recovery equipment differs from system-dependent (passive) equipment in that it:
- System-dependent (passive) recovery equipment may only be used on:
- A recovery cylinder is identified by which color scheme?
- A recovery cylinder should never be filled beyond what percentage of its capacity by weight?
- The main danger of overfilling a recovery cylinder beyond 80 percent is that:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với EPA Section 608 Technician Certification Exam · Quy trình kiểm tra