To avoid overfilling a recovery cylinder past 80 percent, the most reliable method is to:

a.Estimate the level by shaking the cylinder
b.Fill until the hose feels cold
c.Weigh the cylinder with a refrigerant scale and track the net weight against the cylinder's capacity
d.Fill for a fixed number of minutes

Giải thích

The reliable way to stay within the 80 percent limit is to place the cylinder on a refrigerant scale and monitor the net weight against the cylinder's rated capacity, because the limit is defined by weight. Shaking, feeling the hose temperature, or timing the fill cannot accurately measure the charge. A float device or scale with automatic shutoff adds further protection.

Luyện miễn phí toàn bộ 240 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với EPA Section 608 Technician Certification Exam · Quy trình kiểm tra