Services, Grounding & BondingCâu 54 / 120
Overhead service conductors must maintain what minimum clearance from a window that is designed to be opened?
a.6 feet
b.5 feet
c.10 feet
d.3 feet
Giải thích
Service conductors must keep 3 feet of clearance from windows designed to open, doors, porches, balconies, stairs and similar locations. Conductors run above the top level of a window are considered out of reach and are exempt, and the other distances do not appear in this rule.
Trích dẫn luật: 2023 NEC §230.9(A)Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.