Codes & SafetyCâu 108 / 120
Freezing weather makes a water test impractical, so the DWV rough-in is air tested instead. Which combination of test pressure and duration satisfies the code?
a.3 psi held for 10 minutes
b.10 psi held for 30 minutes
c.5 psi, or a mercury column of 10 in, held for at least 15 minutes with no loss of pressure
d.50 psi held for 15 minutes
Giải thích
The DWV air test uses a uniform gauge pressure of 5 psi, or the equivalent 10 in mercury column, maintained for at least 15 minutes without any drop. Three psi is below the required pressure and 10 minutes is short of the required duration. Ten psi and 50 psi are far above what a drainage system is intended to see; 50 psi is the water supply test value, not the DWV value, and that much air can blow test plugs out of a fitting.
Trích dẫn luật: IPC §312.3Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Model plumbing codes are published on a three-year cycle. A state adopts one of those editions with statewide amendments, and a city then adopts the state code with additional local amendments. Which document governs an installation in that city?
- A drainage, waste and vent system is being water tested. Which statement describes the test correctly?
- A high-rise DWV system is water tested in sections. The highest joint in the section currently under test is 28 ft above the building drain, and three more floors of piping continue above that section. To what height above the building drain must the test standpipe extend?
- A water distribution system that will operate at 45 psi working pressure is tested with water. The plumber pumps it to 48 psi, and after 15 minutes the gauge reads 46 psi. How should the result be reported?
- On a set of plumbing drawings, which view shows the vertical arrangement of the DWV piping, the floor-to-floor relationships and the order of the connections, drawn at an angle and generally not to scale?
- A floor plan is drawn at a scale of 1/4 in = 1 ft. A straight run of cold water piping measures 3-1/2 in on the drawing. What is the actual length of that run?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với Journeyman Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra