Water Supply & DistributionCâu 39 / 120
A 24 ft horizontal run of 1/2 in CPVC water distribution pipe is supported at the maximum spacing of 3 ft. What is the minimum number of supports required?
a.6 supports
b.8 supports
c.9 supports
d.12 supports
Giải thích
24 ft divided by 3 ft equals 8 supports at the maximum allowed spacing. The 6 support answer uses the 4 ft spacing allowed for larger plastic pipe, and 12 supports assumes 2 ft spacing, which is more than the code requires. The 9 answer adds an extra support that the calculation does not produce.
Trích dẫn luật: IPC Table 308.5Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A supply outlet has an effective opening of 3/8 in. What minimum air gap must be provided above the flood level rim of the receiving vessel?
- A gauge on the building side of the meter shows a static street pressure of 96 psi with no flow. What does the plumbing code require?
- A 40 ft horizontal run of 3/4 in copper water tube is installed in a ceiling. Using a maximum horizontal support spacing of 6 ft for copper 1-1/2 in and smaller, what is the minimum number of hangers required?
- PEX tubing runs horizontally for 16 ft above a suspended ceiling. Using the maximum horizontal support spacing of 32 in for PEX, what is the minimum number of supports?
- To limit erosion-corrosion and noise, what is the generally accepted maximum design velocity in a copper hot water distribution line?
- A commercial kitchen is being piped with solenoid-operated quick-closing valves on the dishwasher and ice machine supplies. What does the code require on those branches?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với Journeyman Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra