Water Supply & DistributionCâu 49 / 120
What is the maximum lead content permitted in solder and flux used on a potable water piping system?
a.0.2 percent
b.0.25 percent
c.2 percent
d.8 percent
Giải thích
Solder and flux used in potable water piping may not exceed 0.2 percent lead, which is why 50/50 tin-lead solder is prohibited. The 0.25 percent figure is a different limit, the weighted average lead content allowed on the wetted surfaces of pipe, fittings, and fixtures. The 2 percent and 8 percent values are far above any lead-free standard and describe legacy alloys no longer permitted.
Trích dẫn luật: UPC §604.0Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A pressure vacuum breaker protects a lawn irrigation zone whose highest sprinkler head is 42 in above grade. What is the minimum height above grade for the vacuum breaker?
- Which condition makes a pressure vacuum breaker an unacceptable choice for a given cross-connection?
- Which copper tube designation has the heaviest wall thickness and is the type commonly required for an underground water service?
- What is the maximum weighted average lead content permitted on the wetted surfaces of pipe, fittings, and fixtures used to convey water for human consumption?
- Static pressure at the main is 72 psi. Meter loss at design flow is 9 psi, the highest fixture is 26 ft above the meter, and 15 psi residual is required at that fixture. How much pressure is available to overcome friction loss in the piping?
- A flushometer water closet on the top floor requires 20 psi residual. Static pressure is 65 psi, combined meter and backflow preventer loss is 10 psi, and the flush valve is 34 ft above the meter. How much pressure remains for friction loss in the piping and fittings?