Fixtures & Water HeatersCâu 84 / 120
A three compartment pot sink and a food prep sink are being connected in a commercial kitchen. How must the waste from food handling equipment such as a food prep sink be connected to the drainage system?
a.Directly connected through a P-trap with no air gap or air break
b.Indirectly connected through an air gap to an approved receptor
c.Directly connected but only through a grease interceptor
d.Indirectly connected through an air break, which is acceptable for all food equipment
Giải thích
Waste from equipment in which food is stored, prepared, or handled must be indirectly connected by means of an air gap so that sewage cannot back up into food contact surfaces. A direct connection provides no physical break at all, even when a trap or interceptor is present. An air break relies on the pipe extending below the flood rim and is permitted for some indirect wastes but not for food handling equipment.
Trích dẫn luật: IPC §802.1Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A showerhead is rated at the maximum allowable flow. A user showers for 8 minutes. Assuming the head flows at its rated maximum, how much water is used?
- A public restroom is fitted with metering faucets. What is the maximum volume of water each faucet may deliver per metering cycle?
- A closet flange is set on a wood subfloor before the finished tile is installed, and the installer plans to seal the closet to the flange. Which practice is correct?
- A restaurant installs a grease interceptor sized for 30 minutes of retention. If the connected fixtures produce a peak flow of 25 gallons per minute through the flow control device, what liquid capacity does the retention rule call for?
- A grease interceptor is inspected and found to contain accumulated grease and settled solids filling 25 percent of the total liquid depth. What action does the common maintenance standard require?
- A residence has a pressure reducing valve with a check on the incoming water service, and the 40 gallon water heater's relief valve has begun weeping each evening. What is the most likely cause and the correct correction?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với Journeyman Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra