Seismic Detailing and Construction Quality Control

The last area asks how the calculated forces are delivered through real connections in wood, masonry, concrete and steel, and how construction is inspected.

Wood shear walls and diaphragms

Wood-frame capacity comes from sheathing nailing, so the references include the AWC Special Design Provisions for Wind and Seismic (SDPWS-2021). Shear walls are checked for unit shear, aspect ratio, hold-down tension from overturning and sill anchorage. Diaphragms need continuous chords and collectors (drag struts) that carry load to the walls; the collector force is the difference between the diaphragm shear delivered and the wall shear resisted along the line.

Anchorage, ties and continuity

Concrete and masonry walls must be anchored to diaphragms for out-of-plane force, with a minimum that reflects the wall weight and diaphragm flexibility (ASCE 7-16 Section 12.11), and continuous ties must cross the diaphragm so that the anchorage force is developed. Subdiaphragms are used to transfer the anchorage load to the main cross ties. Masonry provisions come from TMS 402/602-16.

Special inspection and quality assurance

The 2022 California Building Code, Chapter 17, requires special inspection and structural observation for designated seismic systems: for example, high-strength bolting, welding, concrete placement, masonry grouting and nailing of high-load diaphragms. The engineer identifies the required inspections in the construction documents; the special inspector reports to the building official and the engineer, and does not direct the contractor's work.