Pre-Inspection: Equipment and Calibration

A short area about the tools of the trade: what a station must have, how it is secured, and where it may be used.

The two inspection systems

The BAR-97 EIS is the tailpipe analyzer. For ASM testing it includes a dynamometer and a NOx bench, because the loaded test measures HC, CO and NOx. The OIS is a computer with a data acquisition device that connects to the vehicle's diagnostic link connector; it has no analyzer. Both exchange data with the Vehicle Information Database (VID). The internet connection must always be on; the OIS cannot run an inspection without it, while the EIS, if communication fails mid-process on a California-registered vehicle after entries are rechecked, completes the inspection as prompted. Both systems are used indoors. The Low Pressure Fuel Evaporative Tester (LPFET) may be operated outside but must be stored inside.

Calibration and security

Calibration uses BAR-approved gases from a BAR-certified gas blender. The analyzer's secured areas may be opened only by BAR and the manufacturer's authorized service representatives. When the EIS requires a calibration or leak check, it locks out testing until the check is passed, so the practical rule for the exam is to follow the prompts and never bypass them. Access to either system is by the inspector's licence number and a biometric device, currently a palm vein scanner. An access code is issued only when a biometric cannot be captured. A compromised code is reported to the BAR field office at once, and no one uses another person's access. Enrollment requires two forms of identification.

Required equipment

STAR stations carry all equipment for all vehicle types. A non-STAR station needs only the equipment for the vehicles it services, so an OIS-only station is allowed. Inspection equipment includes the bar code scanner, fuel cap tester, timing light, hand vacuum pump and the web camera BAR uses for remote observation, which must be full HD (1920 by 1080) at 30 frames per second on USB 3.0. Repair stations add diagnostic tools such as a bidirectional scan tool, lab scope, digital multimeter and fuel pressure gauge.

Key numbers and deadlines

• Camera: 1920 x 1080, 30 frames per second, USB 3.0. • Enrollment: two forms of identification. • LPFET: may be used outdoors, stored indoors.

Worked example

An inspector returns from vacation and the palm scanner will not read. The inspector does not borrow a colleague's log-in. The station contacts BAR; if the biometric cannot be captured, BAR can issue an access code to that inspector.

Exam traps

• The station owner may not open the analyzer's secured areas. • An access code is not a convenience option. • Opacity meters are not part of the Smog Check smoke test.