53 questions

Diagnosing Failures: Evaluating Results

All tests are within specification, but the vehicle failed ASM at another station yesterday. What should be considered?

  • a.The VIR is void and a free retest is owed by the first station
  • b.The first station was dishonest and should be reported to the field office that day
  • c.Conditions at the test, such as engine temperature or an intermittent fault✓
  • d.The standards changed overnight for that model year

A cold catalyst or intermittent problem can cause a fail that is hard to reproduce. Disputes over an inspection go to the Referee.

Diagnosing Failures: Evaluating Results

What makes a diagnosis complete?

  • a.The customer has paid
  • b.A part has been ordered and the customer has approved the estimate
  • c.The root cause is identified and confirmed by testing✓
  • d.A code has been read

A diagnosis that stops at the symptom leads to repeat failures.

Diagnosing Failures: Evaluating Results

Vacuum reads low and steady at 12 in. Hg at idle at sea level. Which condition is consistent with it?

  • a.A burned valve in one cylinder
  • b.Late valve timing or a vacuum leak✓
  • c.A restricted exhaust at idle only
  • d.Normal operation for a warm engine

Steady low vacuum indicates a condition affecting all cylinders. A single valve fault makes the needle flick.