Workers on a leading edge 6 feet or more above a lower level must be protected by:
Explanation
Leading-edge work at 6 feet or more requires conventional fall protection: a guardrail system, a safety net system, or a personal fall arrest system. The alternatives in the wrong answers are real but conditional. A controlled access zone with a safety monitor (b) is available only where the employer has first demonstrated that conventional protection is infeasible or would create a greater hazard, and then only as part of a written fall protection plan. A warning line (c) belongs to low-slope roofing and is set back 6 feet, or 10 where mechanical equipment is in use, never 20. And a plan alone (d) is not a measure - the plan has to specify what will be done instead. On a California job site the equivalent trigger is section 1670(a): falls in excess of 7 1/2 feet.
Law Reference: 29 CFR 1926.501(b)(2); 1926.502(f)-(h), (k); 8 CCR §1670(a)This topic, taught in full in the CSLB Law & Business guide. CSLB Law & Business — Complete Study Guide (2026) — PDF + EPUB, $24.99 · 14-day refund →
Practice all 1632 questions free — no signup required.
Own the complete CSLB Law & Business guide — PDF + EPUB, $24.99 →
Related questions on this topic
- On a California construction site, what is the maximum travel distance from any point of the protected area to the nearest 2A-rated fire extinguisher?
- Good housekeeping on a construction site — keeping walkways clear of debris, scrap, and combustibles — primarily reduces the risk of:
- Danger, caution, and safety instruction signs on a jobsite are used to:
- In steel erection, at what height are workers generally required to be protected from fall hazards?
- On a scaffold, in addition to fall protection, what protects workers BELOW from falling objects such as tools?
- A safety net system used for fall protection must be installed as close as practicable under the work surface, but never more than how far below?