Type I — Small AppliancesQuestion 113 of 240

A technician's self-contained recovery machine is labeled as certified for small-appliance recovery. What performance does that certification confirm it can meet?

a.Reaching 25 mm Hg absolute on low-pressure chillers
b.Recovering 100% of the refrigerant every time
c.Recovering at least 90% when the compressor operates and 80% when it does not (or 4 inches Hg vacuum)
d.Pulling 500 microns for deep dehydration

Explanation

A recovery machine certified for small appliances is verified to reach the required 90% (compressor operating) or 80% (compressor not operating) recovery, or the 4 inches Hg vacuum alternative. No equipment is required to recover 100% of the charge. Deep-vacuum micron levels apply to evacuation and dehydration on larger systems, not to the small-appliance recovery standard.

Law Reference: 40 CFR §82.156