Codes & SafetyPregunta 111 de 120
A floor plan is drawn at a scale of 1/4 in = 1 ft. A straight run of cold water piping measures 3-1/2 in on the drawing. What is the actual length of that run?
a.3 ft 6 in
b.10 ft 6 in
c.14 ft
d.17 ft 6 in
Explicación
At 1/4 in = 1 ft, every full inch on the drawing represents 4 ft, so 3.5 in x 4 ft = 14 ft. Reading 3 ft 6 in simply repeats the measured inches as feet and ignores the scale entirely. Ten feet six inches comes from multiplying by 3 instead of 4, and 17 ft 6 in comes from multiplying by 5. Checking the answer the other way confirms it: 14 ft x 1/4 in per ft = 3.5 in on paper.
Practica las 120 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- Freezing weather makes a water test impractical, so the DWV rough-in is air tested instead. Which combination of test pressure and duration satisfies the code?
- A water distribution system that will operate at 45 psi working pressure is tested with water. The plumber pumps it to 48 psi, and after 15 minutes the gauge reads 46 psi. How should the result be reported?
- On a set of plumbing drawings, which view shows the vertical arrangement of the DWV piping, the floor-to-floor relationships and the order of the connections, drawn at an angle and generally not to scale?
- A site plan shows the invert elevation of a building sewer as 102.50 ft at the upstream end and 101.90 ft at the downstream end, with 48 ft of run between the two points. What is the slope of the sewer in inches per foot?
- A building sewer runs 62 ft from the building drain to the connection at the main and is to be graded at 1/4 in per foot. The invert elevation at the upstream end is 100.00 ft. What is the invert elevation at the downstream end?
- A crew is setting sewer pipe in a trench 5 ft 6 in deep with vertical walls cut in previously disturbed soil. No sloping, shoring or shielding has been installed. What does OSHA require before a worker enters?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con Journeyman Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos