Water Supply & DistributionPregunta 40 de 120

PEX tubing runs horizontally for 16 ft above a suspended ceiling. Using the maximum horizontal support spacing of 32 in for PEX, what is the minimum number of supports?

a.3 supports
b.4 supports
c.5 supports
d.6 supports

Explicación

Convert first: 16 ft equals 192 in, and 192 divided by 32 equals 6 supports. The 4 and 3 answers come from using 48 in or 72 in spacing, which apply to rigid materials, not flexible PEX. Five supports would leave one span longer than 32 in and would allow the tubing to sag.

Referencia Legal: IPC Table 308.5