Water Supply & DistributionPregunta 52 de 120
A flushometer water closet on the top floor requires 20 psi residual. Static pressure is 65 psi, combined meter and backflow preventer loss is 10 psi, and the flush valve is 34 ft above the meter. How much pressure remains for friction loss in the piping and fittings?
a.About 35.0 psi
b.About 25.3 psi
c.About 14.7 psi
d.About 20.3 psi
Explicación
Elevation loss is 34 x 0.433 = 14.72 psi, so 65 - 10 - 14.72 - 20 = 20.3 psi for friction. The 35.0 psi answer ignores the elevation loss, and 25.3 psi uses a 15 psi residual instead of the 20 psi a flushometer needs. The 14.7 psi choice is the elevation loss itself, not the friction allowance.
Referencia Legal: UPC §610.0Practica las 120 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- What is the maximum lead content permitted in solder and flux used on a potable water piping system?
- What is the maximum weighted average lead content permitted on the wetted surfaces of pipe, fittings, and fixtures used to convey water for human consumption?
- Static pressure at the main is 72 psi. Meter loss at design flow is 9 psi, the highest fixture is 26 ft above the meter, and 15 psi residual is required at that fixture. How much pressure is available to overcome friction loss in the piping?
- A sizing problem leaves 24 psi available for friction loss. The measured developed length to the most remote fixture is 160 ft, and fittings are estimated to add 50 percent to that length. What is the allowable friction loss per 100 ft of pipe?
- A dwelling unit contains one flush tank water closet (2.5 WSFU), two lavatories (1.0 WSFU each), one bathtub with shower (4.0 WSFU), one kitchen sink (1.5 WSFU), one dishwasher (1.5 WSFU), and one clothes washer (4.0 WSFU). What is the total water supply fixture unit load?
- Using the standard fixture unit to gpm conversion curve, what happens to the estimated demand when the total water supply fixture unit load on a system is doubled?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con Journeyman Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos