Infection Prevention & SafetyPregunta 100 de 100
A surgeon asks a sterile processing technician to release an instrument set that has not completed its sterilization cycle because the next case is waiting. What is the professional and correct response?
a.Release the set, because the surgeon holds clinical authority over the department
b.Release the set and document the surgeon's name as the person responsible
c.Release the set only if a Class 1 process indicator is attached
d.Decline to release the set, explain that the process is incomplete, offer alternatives such as another available set or a validated cycle, and escalate to the supervisor if the request continues
Explicación
A technician's professional scope includes refusing to release items that have not completed a validated process, because patient safety outcomes depend on process integrity rather than schedule pressure. The correct approach is to communicate respectfully, offer workable alternatives, and escalate through the chain of command when necessary. Documenting another person's name does not transfer accountability, and an external process indicator provides no evidence that a cycle was completed.
Practica las 100 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- A technician wants to break the chain of infection during instrument reprocessing. Which action most directly interrupts the mode of transmission link?
- Under the OSHA Bloodborne Pathogens standard, what must the employer provide to an employee with occupational exposure risk?
- A technician receives a tray from a patient with no known infection and no isolation precautions. What principle of standard precautions applies?
- A new instrument detergent is delivered to the department. Where does the technician find the chemical's hazards, personal protective equipment requirements, and first aid measures?
- A technician opens a case cart and finds loose scalpel blades and suture needles mixed in with the instruments. What is the correct action?
- Which workstation adjustment best applies ergonomic principles in the decontamination area?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con HSPA Certified Registered Central Service Technician (CRCST) Exam · Cómo revisamos