DecontaminationPregunta 13 de 100
A washer-disinfector is being validated and the question arises about which water quality is required for the final rinse. What is correct?
a.Critical water, which has been treated to remove minerals, ions, and endotoxins
b.Utility water straight from the municipal tap
c.Softened water only, with no additional treatment
d.Distilled water heated to at least 180 degrees F but not otherwise treated
Explicación
Critical water is extensively treated by processes such as reverse osmosis or deionization so that the final rinse does not deposit minerals, ions, or endotoxin residues on devices that will contact sterile tissue. Utility water is acceptable for flushing, washing, and initial rinsing but leaves residues on the final product. Softening alone removes hardness ions but not the full range of contaminants, and temperature does not substitute for treatment.
Referencia Legal: AAMI ST79Practica las 100 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- A technician loads a mixed basket of stainless steel clamps, chrome-plated retractors, and aluminum instruments into the ultrasonic cleaner. What is the problem with this load?
- A technician fills the wash sink with very hot water to speed up cleaning. Why must manual cleaning water stay below approximately 140 degrees F (60 degrees C)?
- Most instrument manufacturers specify a neutral pH detergent for routine cleaning. What pH range is considered neutral?
- A technician is scrubbing a hinged instrument with a brush at the decontamination sink and is spraying water droplets into the air. What is the correct technique?
- What is the purpose of the elevated-temperature rinse phase, often around 180 degrees F or higher, in a washer-disinfector cycle?
- A department is writing its quality plan and must set a frequency for cleaning verification testing of its mechanical washers. What should the plan specify?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con HSPA Certified Registered Central Service Technician (CRCST) Exam · Cómo revisamos