Core TradesCâu 104 / 700
Where a sloped shingle roof meets a vertical sidewall, the correct flashing method is:
a.Step flashing woven with each shingle course, extending up the wall behind the siding
b.A single continuous piece of flashing laid over all shingles
c.Sealant only at the joint
d.No flashing if the shingles are close to the wall
Giải thích
A roof-to-sidewall junction requires step flashing: individual L-shaped pieces interwoven with each shingle course and extending up behind the wall covering, so water is shingled over each piece. A single continuous strip, sealant alone, or no flashing all lead to leaks.
Trích dẫn luật: 2025 CA Building Code, Chapter 15 (Roof Assemblies)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A high-efficiency (condensing) furnace produces acidic condensate. This condensate must be:
- Supply and return ducts installed in an unconditioned attic are typically required to be insulated and sealed MAINLY to:
- At the intersection of two sloping roof planes, water collects and flows in a channel. The flashing installed in this channel is called:
- On a low-slope shingle roof, underlayment courses must be lapped so water sheds over each lower course. The MAIN reason for the larger head and side laps on low slopes is:
- Asphalt shingles are blowing off in high winds shortly after installation. The MOST likely installation error is:
- Counter flashing at a chimney is installed so that its top edge is embedded in or tucked into a mortar joint of the masonry, MAINLY to:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra