A standard plumbing trap must maintain a liquid seal with a depth in the range of:
a.2 to 4 inches
b.1/2 to 1 inch
c.5 to 7 inches
d.8 to 10 inches
Giải thích
A trap seal of 2 to 4 inches blocks sewer gas while resisting evaporation and siphonage. A shallower seal (under 2 inches) can be blown or evaporated away, letting gas into the building. A seal deeper than 4 inches tends to collect solids and self-siphon, and is not standard.
Trích dẫn luật: 2025 CA Plumbing Code §1002.0Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.