A 3-inch-diameter horizontal drainage pipe should be installed at a MINIMUM slope of:
a.1/16 inch per foot
b.1/2 inch per foot
c.1/4 inch per foot
d.1/8 inch per foot
Giải thích
Drainage pipes 3 inches in diameter and larger may be sloped at a minimum of 1/8 inch per foot, which keeps solids in suspension without draining the water too fast. Pipes 2-1/2 inches and smaller need a steeper 1/4 inch per foot. 1/16 inch per foot is too flat to self-scour.
Trích dẫn luật: 2025 CA Plumbing Code §708.0Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.