Core TradesCâu 148 / 700
Under the California Energy Code, supply ducts run through an unconditioned attic must generally be insulated to a MINIMUM of:
a.R-4.2
b.R-6
c.R-13
d.R-8
Giải thích
Ducts located in unconditioned space such as an attic must have at least R-8 insulation to limit conductive heat loss and gain where temperatures are extreme. R-6 applies to ducts in more moderate locations, R-4.2 is below current requirements, and R-13 exceeds the minimum for ducts.
Trích dẫn luật: 2025 CA Energy Code §150.0(m)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A fuel-burning furnace located in a confined space requires combustion-air openings primarily to:
- Taking return air for a residential forced-air furnace from a garage is prohibited primarily to prevent:
- A room measures 12 ft by 15 ft with an 8-ft ceiling. To provide 6 air changes per hour, what mechanical ventilation airflow is required?
- Without a booster fan, the MAXIMUM developed length of a residential clothes-dryer exhaust duct (before deductions for fittings) is generally:
- A secondary condensate drain pan or overflow provision under a cooling coil is required primarily to:
- On a roof slope of 4:12 or greater covered with asphalt shingles, the underlayment must consist of at least:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra