For an enclosed attic without a vapor retarder or balanced venting, the net free ventilating area must generally be at least what fraction of the vented attic floor area?
a.1/50
b.1/150
c.1/300
d.1/600
Giải thích
The baseline requirement is a net free vent area of at least 1/150 of the attic floor area. The 1/300 ratio is allowed only when specific conditions such as a vapor retarder or balanced high-and-low venting are met; 1/50 and 1/600 are not the standard code fractions.
Trích dẫn luật: 2025 CA Residential Code, R806 (Roof Ventilation)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.