For window head flashing to work correctly with a water-resistive barrier, the barrier above the window must be lapped so that it:
a.Tucks behind the flashing at the bottom edge
b.Is sealed only with caulk over the flashing face
c.Is cut away entirely above the window
d.Overlaps the top of the flashing in shingle fashion so water drains outward
Giải thích
The weather barrier above the opening must lap over the top edge of the head flashing shingle-style so any water running down the wall is directed to the outside face. Tucking it behind, relying on caulk alone, or removing the barrier lets water get behind the flashing and into the wall.
Trích dẫn luật: 2025 CA Building Code, Chapter 14 (Exterior Walls)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- For an enclosed attic without a vapor retarder or balanced venting, the net free ventilating area must generally be at least what fraction of the vented attic floor area?
- To completely fill the cavity of a nominal 2x6 wood-framed exterior wall, which batt insulation R-value is most typically specified?
- A blower-door test performed on a completed home measures PRIMARILY the building's:
- A vapor retarder placed directly under a concrete slab-on-ground in habitable space is commonly required to be polyethylene sheeting with a MINIMUM thickness of:
- A radiant barrier installed in an attic reduces summer heat gain PRIMARILY by:
- A wall assembly has a total thermal resistance of R-20. What is its approximate overall U-factor (heat-transfer coefficient)?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra