Framing & StructuralCâu 339 / 700

Compared with solid-sawn joists, why are field notches and unauthorized holes especially damaging to engineered wood products such as I-joists and LVL?

a.They are made of steel
b.They are unaffected by cuts
c.Their strength depends on thin engineered flanges/laminations, so unauthorized cuts remove critical load-carrying material
d.They gain strength when cut

Giải thích

Engineered products concentrate their strength in thin, carefully placed flanges and laminations, so an unauthorized notch or hole removes exactly the material carrying the load and can cause sudden failure, unlike solid lumber that has some reserve. They are not steel, are certainly affected by cuts, and never gain strength from cutting.

Trích dẫn luật: 2025 CA Residential Code §R502.8