Framing & StructuralCâu 340 / 700
On braced/shear walls, code requires a plate washer at each anchor bolt between the sill plate and nut. A common minimum size is:
a.1 inch by 1 inch by 1/16 inch
b.3 inch by 3 inch by 0.229 inch
c.2 inch round by 1/8 inch
d.No washer is needed if a nut is used
Giải thích
For braced-wall sill anchorage in seismic areas, the code commonly requires a plate washer at least 3 inch by 3 inch by 0.229 inch thick under the nut, so seismic uplift cannot pull the sill over the bolt head. A tiny 1x1 or thin round washer is inadequate, and a nut alone does not spread the load.
Trích dẫn luật: 2025 CA Residential Code §R602.11.1Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- CALCULATION: An engineered LVL header is specified as a 3-1/2 inch wide member built up from plies that are each 1-3/4 inch thick. How many plies are laminated together?
- Engineered rim board is often chosen over solid sawn lumber at the perimeter of an I-joist floor mainly because it:
- Compared with solid-sawn joists, why are field notches and unauthorized holes especially damaging to engineered wood products such as I-joists and LVL?
- For a bolted sill plate, the code requires a minimum number of anchor bolts per plate piece and a limit on bolt distance from plate ends. Which statement is correct?
- CALCULATION: A sill plate on a 30-foot wall uses anchor bolts spaced at the 6-foot maximum, with a bolt required near each end. Approximately how many anchor bolts are needed along that wall?
- In a wood-framed building, what is the PRIMARY role of a floor or roof diaphragm in the lateral system?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra