Framing & StructuralCâu 350 / 700
Behind exterior cement plaster (stucco) applied over wood-based sheathing, how many layers of water-resistive barrier does the code generally require?
a.One layer
b.Two layers of a water-resistive barrier (for example, two layers of Grade D paper)
c.No barrier if the stucco is thick enough
d.Only a vapor barrier on the inside
Giải thích
Over wood-based sheathing, stucco assemblies generally require two layers of water-resistive barrier, because fresh stucco bonds to and can compromise the first layer, so the second layer maintains a continuous drainage plane. One layer, no barrier, and an interior-only vapor barrier do not meet the two-layer stucco requirement.
Trích dẫn luật: 2025 CA Residential Code §R703.6.3Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- What is the main purpose of a hold-down (tie-down) anchor at the end post of a narrow shear wall?
- A 'collector' or 'drag strut' in a lateral system does what?
- To transfer shear from a diaphragm or wall into the framing, the connection of sheathing to the boundary members depends MOST on which factor?
- A weep screed at the base of a stucco wall must be located at least how far above adjacent surfaces?
- CALCULATION: Cement plaster control joints are recommended to divide large wall areas into panels not exceeding 144 square feet. On a wall panel 8 feet tall, at about what horizontal spacing should control joints fall to stay within that limit?
- When metal lath for three-coat stucco is fastened to a wood-framed wall, how far should the fasteners penetrate the framing?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra