When installing tongue-and-groove wood structural panel subflooring, which practice BEST reduces squeaks and improves diaphragm performance?
a.Butting panel edges tightly with no gap
b.Nailing only at panel corners
c.Gluing the panels to the joists in addition to fastening
d.Laying all end joints on a single joist in a continuous line
Giải thích
Field-gluing the subfloor to the joists with construction adhesive in addition to nailing or screwing greatly reduces squeaks and stiffens the diaphragm. Panel edges need a small expansion gap, not a tight butt; fastening only at corners leaves the field unsupported; and aligning all end joints on one line creates a weak, hinge-like seam rather than a staggered layout.
Trích dẫn luật: 2025 CA Residential Code §R503Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- CALCULATION: Two stair carriages (stringers) are each cut from a 2x12 that is 14 feet long. Using nominal dimensions, how many total board feet of lumber is that?
- A spiral stairway is permitted in a dwelling under special rules. Which requirement is characteristic of a code-compliant spiral stair?
- For a conventionally framed one-story dwelling using 2x4 studs, what is the MAXIMUM on-center spacing generally permitted for load-bearing wall studs supporting a roof and ceiling only?
- A gable roof has a total run of 12 feet (horizontal from wall to ridge) and a slope of 6:12. Ignoring ridge and overhang, what is the approximate line length of a common rafter along the slope?
- Under the residential code, what is the MAXIMUM permitted riser height for a stairway serving a dwelling?
- For a dwelling stairway, what is the MINIMUM tread depth (run) required, measured horizontally between the leading edges of adjacent treads?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra