Framing & StructuralCâu 446 / 700
When metal lath is applied to a wood-framed wall to receive three-coat cement plaster, the lath fasteners should penetrate the framing members by at least approximately how much?
a.1/8 inch
b.1/4 inch
c.3/4 inch
d.No penetration into framing is needed if the sheathing holds the lath
Giải thích
Lath must be firmly anchored so the heavy plaster does not sag or crack; fasteners should penetrate the supporting framing by about 3/4 inch. Penetrations of 1/8 or 1/4 inch are too shallow to hold the load, and relying on sheathing alone without engaging framing leaves the lath inadequately secured.
Trích dẫn luật: 2025 CA Residential Code §R703.7Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- For a wood structural panel shear wall to develop its rated capacity, how must the panel edges be treated where sheets meet?
- Exterior wood siding, sheathing, or trim that is NOT preservative-treated or naturally durable must generally be kept at least how far above exposed earth?
- On a wood-framed wall receiving exterior cement plaster (stucco), a weep screed must be installed at the base of the wall at a MINIMUM of how high above adjacent earth and above paved surfaces?
- Where an exterior deck beam bears on a supporting post, what is the BEST practice for the beam-to-post connection?
- How many board feet are contained in 15 framing members that are each nominal 2x10 and 16 feet long? (Board feet per piece = nominal thickness in inches times nominal width in inches times length in feet, divided by 12.)
- Under the raised floor of a dwelling, short stud walls between the foundation and the first-floor framing (cripple walls) exceeding a nominal height must be braced primarily to resist what?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra