Core TradesCâu 72 / 700
A driveway slab cracks in a fairly straight line directly over a buried utility trench that was backfilled. The MOST likely cause is:
a.Too much cement in the mix
b.Excessive air entrainment
c.Differential settlement of poorly compacted trench backfill under the slab
d.Curing the slab too long
Giải thích
A crack tracking a backfilled trench indicates the subgrade settled unevenly because the trench backfill was not compacted to match the surrounding soil, leaving the slab unsupported over the trench. Cement content, air entrainment, and extended curing do not create a crack that follows a trench line.
Trích dẫn luật: 2025 CA Building Code, Chapter 19 (Concrete)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- CALCULATION: A rectangular column is 18 in by 18 in in cross-section and 10 feet tall. Ignoring reinforcement, how many cubic yards of concrete does it contain?
- A concrete supplier delivers a load with a measured slump much higher than ordered. Before rejecting or accepting, the BEST assumption about the likely cause and its effect is:
- During hot-weather concreting at 95 degrees F with dry wind, the MOST important immediate practice to prevent surface defects is to:
- Control joints (contraction joints) are tooled or saw-cut into a slab primarily to:
- CALCULATION: Concrete costs $165 per cubic yard. A footing pour needs 100 cubic feet of concrete plus 8 percent for waste. What is the approximate concrete cost?
- A 120-volt lighting circuit runs a long distance and the fixtures at the far end appear dim. The MOST likely electrical cause and its fix is: