Load & DesignCâu 15 / 110
Friction rate in duct design is typically expressed in which units?
a.CFM per square foot
b.BTU per hour
c.Inches of water column per 100 feet of duct
d.Feet per minute
Giải thích
Friction rate expresses the pressure loss per unit length of duct, in inches of water column per 100 feet. In Manual D, the available static pressure and total effective length set the design friction rate used to size ducts. A higher friction rate yields smaller, higher-velocity ducts.
Luyện miễn phí toàn bộ 110 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Under the California Mechanical Code, when is a permit generally required for HVAC work?
- What is the primary purpose of a Manual J block load versus a room-by-room load?
- If a home has a calculated cooling load of 30,000 BTU/hr, what nominal equipment size is the closest match?
- Air velocity in a duct is calculated by dividing airflow (CFM) by what?
- A branch duct must deliver 200 CFM at a velocity of about 600 feet per minute. Approximately what free area is required?
- Under California energy standards, duct leakage in many new and altered systems must be verified by which method?