Cấp nước & Phân phốiCâu 10 / 360
Estimating demand for a small apartment, you total the fixtures as: 8 lavatories (1 WSFU each), 6 water closets with flush tanks (2.5 WSFU each), and 4 showers (2 WSFU each). What is the total water supply fixture unit (WSFU) load?
a.23 WSFU
b.31 WSFU
c.46 WSFU
d.18 WSFU
Giải thích
Lavatories = 8 x 1 = 8; water closets = 6 x 2.5 = 15; showers = 4 x 2 = 8; total = 8 + 15 + 8 = 31 WSFU. The other totals result from arithmetic errors such as omitting a fixture group or using incorrect unit values.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §610.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- You are supporting horizontal 1-inch copper water tube. Per the code hanger and support spacing table, what is the maximum horizontal spacing between supports for copper tube 1-1/2 inch and smaller?
- A plumber is installing horizontal PEX tubing in a residence. What is the typical maximum horizontal support spacing required for PEX tubing?
- A quick-closing solenoid valve on a commercial dishwasher is causing banging pipes. What does the code require to control the resulting water hammer?
- A lawn sprinkler system has no chemical injection and no possibility of backpressure, only back-siphonage under continuous pressure. Which device is the appropriate minimum protection?
- A residence has a closed water supply system because the water meter contains a check valve and a pressure regulator. As the water heater heats water, pressure spikes dangerously. What does the code require to relieve this?
- Which of the following is an approved standard material for potable cold and hot water distribution piping inside a building?