A plumber is installing horizontal PEX tubing in a residence. What is the typical maximum horizontal support spacing required for PEX tubing?
a.10 feet
b.8 feet
c.6 feet
d.32 inches
Giải thích
Because PEX is flexible, the code requires closer support, with a maximum horizontal spacing of about 32 inches for PEX tubing. Spacings of 6, 8, or 10 feet apply to rigid materials such as copper or steel and would allow excessive sag in PEX.
Trích dẫn luật: 2022 California Plumbing Code (CPC) Table 313.3Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- An atmospheric vacuum breaker (AVB) is installed to protect a hose connection. What installation condition must be satisfied for an AVB to be used correctly?
- A plumber connects PEX tubing to a residential water heater. What does the code require at the hot-water outlet connection?
- You are supporting horizontal 1-inch copper water tube. Per the code hanger and support spacing table, what is the maximum horizontal spacing between supports for copper tube 1-1/2 inch and smaller?
- A quick-closing solenoid valve on a commercial dishwasher is causing banging pipes. What does the code require to control the resulting water hammer?
- Estimating demand for a small apartment, you total the fixtures as: 8 lavatories (1 WSFU each), 6 water closets with flush tanks (2.5 WSFU each), and 4 showers (2 WSFU each). What is the total water supply fixture unit (WSFU) load?
- A lawn sprinkler system has no chemical injection and no possibility of backpressure, only back-siphonage under continuous pressure. Which device is the appropriate minimum protection?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra