You are supporting horizontal 1-inch copper water tube. Per the code hanger and support spacing table, what is the maximum horizontal spacing between supports for copper tube 1-1/2 inch and smaller?
a.12 feet
b.10 feet
c.6 feet
d.3 feet
Giải thích
The support spacing table lists 6 feet as the maximum horizontal support spacing for copper water tube 1-1/2 inch and smaller. 12 feet applies to threaded steel pipe, 10 feet to larger copper, and 3 feet is closer to the spacing for CPVC of small diameter.
Trích dẫn luật: 2022 California Plumbing Code (CPC) Table 313.3Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A commercial irrigation system injects fertilizer chemicals into the line and operates under continuous pressure with potential backpressure. Which backflow assembly is required for this high-hazard cross-connection?
- An atmospheric vacuum breaker (AVB) is installed to protect a hose connection. What installation condition must be satisfied for an AVB to be used correctly?
- A plumber connects PEX tubing to a residential water heater. What does the code require at the hot-water outlet connection?
- A plumber is installing horizontal PEX tubing in a residence. What is the typical maximum horizontal support spacing required for PEX tubing?
- A quick-closing solenoid valve on a commercial dishwasher is causing banging pipes. What does the code require to control the resulting water hammer?
- Estimating demand for a small apartment, you total the fixtures as: 8 lavatories (1 WSFU each), 6 water closets with flush tanks (2.5 WSFU each), and 4 showers (2 WSFU each). What is the total water supply fixture unit (WSFU) load?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra