Thoát nước, Nước thải & Thông hơiCâu 122 / 360
A vent penetrates a roof deck that is also used as a sun deck or walking surface. How high must the vent terminal extend above that roof?
a.6 inches
b.At least 7 feet (2134 mm) above the roof
c.3 feet
d.36 inches
Giải thích
When a roof is used for purposes other than weather protection (such as a deck or garden), a vent must terminate at least 7 feet above the roof surface. This keeps sewer gases well above the breathing zone of people using the roof.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §906.1Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A residential clothes washer standpipe is assigned what DFU value and minimum trap size?
- A horizontal branch serves two water closets (3 DFU each), two lavatories (1 DFU each), and two showers (2 DFU each). What is the minimum branch size?
- A plumber terminates a vent pipe through a residential roof that is used only for weather protection. What is the minimum height the vent must extend above the roof surface?
- A vent terminal is located 8 feet horizontally from an openable window. Under the CPC it must either terminate at least 10 feet away or…
- An air admittance valve (AAV) serving an individual fixture must be installed a minimum distance above the horizontal branch drain it serves. What is that minimum?
- Where are air admittance valves (AAVs) prohibited from being installed?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra