Cấp nước & Phân phốiCâu 20 / 360
A janitor's service sink has a hose thread faucet used with cleaning chemicals. What is the simplest code-recognized protection against back-siphonage at that outlet?
a.A gate valve upstream
b.A pressure regulator
c.A larger drain
d.A hose connection (hose bibb) vacuum breaker on the outlet
Giải thích
A hose connection (hose bibb) vacuum breaker installed on the threaded outlet protects against back-siphonage where a hose could submerge in chemicals. A gate valve, pressure regulator, and larger drain do not provide backflow protection at the hose outlet.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §603.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- When sizing water piping using the fixture unit method, why is the total demand in gpm always less than the simple sum of every fixture's peak flow?
- A flushometer (flush valve) water closet is being served. Compared with a flush-tank water closet, what does the flushometer require from the water distribution design?
- A water service run has a developed length of 120 feet with an available pressure of 60 psi and a required residual of 15 psi at the highest fixture, which is 25 feet above the meter. Roughly how much pressure remains for friction loss in the piping (ignoring meter and fitting losses)?
- You are supporting horizontal CPVC hot water pipe, 1 inch and smaller. What is the maximum horizontal support spacing typically required?
- A reduced pressure principle assembly (RP) discharges water from its relief port during a fouling event. Where must the relief port discharge terminate?
- A hot water recirculation loop is added so users get hot water quickly at a remote fixture. What is the main plumbing purpose of the recirculation return line?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra