Thiết bị & Bình nước nóngCâu 220 / 360
An outdoor hose bibb (sillcock) must be protected against backflow by:
a.an expansion tank
b.a pressure-reducing valve
c.an atmospheric or listed hose-connection vacuum breaker
d.a check valve on the water heater
Giải thích
A hose bibb can create a cross-connection when a hose is submerged in contaminated water, so it must have a hose-connection vacuum breaker (or be a listed anti-siphon type). This device admits air to break any back-siphonage. It protects the potable supply from garden or utility contaminants.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §603.5.7Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.