A gas furnace uses a draft hood and relies on natural draft to move flue gases up the vent. This describes which general appliance venting category?
a.A direct-vent sealed-combustion appliance
b.A power-vented appliance requiring PVC
c.A Category I appliance with a draft hood venting by natural draft
d.An unvented decorative appliance
Giải thích
An appliance with a draft hood that vents by natural draft and produces non-condensing, low-pressure flue gases is generally a Category I appliance, typically vented with Type B vent or a lined masonry chimney. Direct-vent and power-vent appliances use sealed or mechanically assisted venting and different materials. Matching the vent to the appliance category is essential for safe combustion product removal.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- What best describes CSST used in gas distribution?
- Two runs leave the meter: Run A is 55 feet to the farthest outlet; Run B is 30 feet. Using the longest-length method, which length column governs sizing of the entire system?
- An appliance shutoff valve is being installed. Which condition satisfies the accessibility requirement?
- Why must clearances to combustibles for a single-wall metal vent connector and for Type B vent be respected during installation?
- A branch serves two appliances downstream: a 30,000 BTU/hr wall heater and a 120,000 BTU/hr furnace. In natural gas cfh, what demand governs that branch?
- A sediment trap is typically built from a tee and a nipple. What is a reasonable minimum length for the capped drip nipple so it can actually collect debris?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra