Đường ống gaCâu 255 / 360
A sediment trap is typically built from a tee and a nipple. What is a reasonable minimum length for the capped drip nipple so it can actually collect debris?
a.About 1/2 inch
b.About 3 inches
c.About 12 inches minimum by code everywhere
d.Length does not matter
Giải thích
The capped drip leg needs enough depth, commonly on the order of about 3 inches, to actually collect condensate and debris below the run of the tee. A stub that is too short cannot trap anything. Follow the appliance instructions and adopted code, which specify the required configuration and minimum dimension.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A gas furnace uses a draft hood and relies on natural draft to move flue gases up the vent. This describes which general appliance venting category?
- Why must clearances to combustibles for a single-wall metal vent connector and for Type B vent be respected during installation?
- A branch serves two appliances downstream: a 30,000 BTU/hr wall heater and a 120,000 BTU/hr furnace. In natural gas cfh, what demand governs that branch?
- A line pressure regulator on a 2 psi system has a vent limiter or vent connection. Where must a regulator vent generally terminate?
- When installing CSST, which document must be followed for support spacing, fittings, bonding, and physical protection?
- Which test medium is acceptable for pressure-testing gas piping?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra