Lập kế hoạch & Dự toánCâu 273 / 360
For a slab-on-grade house, which sequence of plumbing inspections is correct?
a.Final, then rough-in, then underground
b.Underground (groundwork), then rough-in/top-out, then final
c.Rough-in, then underground, then final
d.Only a single final inspection is required
Giải thích
Work is inspected in the order it is buried or concealed: underground drains under the slab first, then the rough-in/top-out once walls are framed, and finally the trim-out when fixtures are set. Each stage is a hold point that must pass before the next is covered. Sequencing inspections wrong causes failed or missed approvals and rework.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- On a set of plumbing drawings, a supply line labeled with the abbreviation "CW" represents which system?
- On plumbing plans, piping that runs below the floor slab or underground is most commonly drawn using which line type?
- During construction the rough-in (rough) plumbing inspection is generally performed at what point?
- For most commercial plumbing jobs, who is normally responsible for obtaining the plumbing permit before work starts?
- You are doing a material takeoff from an isometric of a bathroom group. The riser drops through one floor and makes three horizontal offsets, each requiring a pair of 90° bends. How many 90° elbows should you count for those offsets alone?
- You are laying out a 2-inch horizontal drainage pipe. What minimum slope does the CPC require for a pipe this size?