When sizing a building sewer during layout, the required size is based primarily on what?
a.The total drainage fixture units carried and the slope, per the code's sizing table
b.The color of the fixtures
c.The number of electrical outlets
d.The height of the roof
Giải thích
CPC 718.0 and its referenced tables size the building sewer from the total drainage fixture unit (DFU) load it carries at a given slope. More fixture units or a flatter slope require a larger pipe. Sizing from DFUs on the plan ensures the sewer can carry peak flow without surcharging.