For vertical copper water tube, how must risers be supported according to the support requirements?
a.No vertical support is ever required
b.Only at the top of the building
c.Every 40 feet regardless of stories
d.At each story or at intervals not exceeding about 10 feet
Giải thích
Vertical copper piping must be supported at each story or at intervals not exceeding roughly 10 feet so the weight is not carried entirely by lower connections. Claiming no support, top-only support, or a flat 40-foot interval regardless of stories does not meet the support requirements.
Trích dẫn luật: 2022 California Plumbing Code (CPC) Table 313.3Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- On which fixtures does the code most specifically require water hammer arrestors?
- A pressure vacuum breaker (PVB) is selected for a landscape irrigation system. What is the minimum installation height for a PVB relative to the highest downstream head or outlet?
- Two fixtures on a branch each require 4 gpm. If the branch is sized so the combined design demand (with diversity) is about 6 gpm rather than 8 gpm, what principle is being applied?
- A commercial building connects to a boiler that uses chemical additives and is served from the potable main. What premise-isolation protection does the code generally require at the service?
- A fixture requires a minimum flow (residual) pressure of 8 psi to operate correctly. During peak demand your calculation shows only 5 psi available at that fixture. What is the correct interpretation?
- Which characteristic makes CPVC acceptable for hot water distribution where standard PVC is not?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra