For a 3 inch trap arm, the maximum developed length to the vent is:
a.5 feet
b.8 feet
c.6 feet
d.10 feet
Giải thích
A 3 inch trap arm may run a maximum developed length of 6 feet to its vent. The 5 foot value is for a 2 inch arm and 10 feet is for a 4 inch arm; 8 feet is not a listed value. Longer runs on this size require an additional or relocated vent.