Thoát nước, Nước thải & Thông hơiCâu 83 / 360
A single wet vent may serve fixtures within a maximum of how many bathroom groups?
a.1
b.3
c.2
d.4
Giải thích
The CPC allows a wet vent to serve any combination of fixtures within a maximum of two bathroom groups on the same floor. Limiting it to one group is stricter than the code allows, and three or four groups exceed the wet-vent limit and require additional venting.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §908.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Under the CPC, installing two traps in series on a single fixture (double trapping) is:
- Crown venting, where the vent connects at the top of the trap crown, is:
- The use of an S-trap on a fixture is:
- A circuit vent may serve a battery of not more than how many fixtures?
- A combination waste and vent system is typically used for:
- Horizontal vent piping must be graded so that it:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra