Recovery & RecyclingCâu 236 / 240
Using recovery equipment made after November 15, 1993, an appliance using CFC-12 and holding less than 200 pounds must be evacuated to:
a.0 inches Hg vacuum
b.4 inches Hg vacuum
c.15 inches Hg vacuum
d.10 inches Hg vacuum
Giải thích
For other high-pressure refrigerants such as CFC-12, post-1993 equipment must evacuate an appliance under 200 pounds to 10 inches of mercury vacuum, and 200 pounds or more to 15 in Hg. HCFC-22 has its own lower numbers, and 25 mm Hg absolute is for low-pressure. Memorizing the table by refrigerant and size is essential.
Trích dẫn luật: 40 CFR §82.156Luyện miễn phí toàn bộ 240 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Which sequence correctly lists the three processes from least to most thorough?
- Storing a filled recovery cylinder in a hot vehicle trunk in summer is dangerous mainly because:
- A refrigerant recovered from an appliance still contains oil, moisture, and acid. To make it usable again on-site, the technician would:
- The primary reason recovery cylinders are color-coded gray with a yellow top is to:
- Recovering refrigerant to the required evacuation level is required before a technician may:
- A technician should retain proof of certification and, where applicable, recovery and servicing records because:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với EPA Section 608 Technician Certification Exam · Quy trình kiểm tra