Gas PipingCâu 101 / 120

Gas piping passes through a concrete foundation wall below grade. What does the code require at that point?

a.The pipe must be cast solidly into the concrete with no sleeve
b.A union must be installed inside the wall for future service
c.The pipe may be run through the wall only if it is PE
d.The pipe must be protected against corrosion and breakage, typically by a sleeve sealed at one end

Giải thích

Piping that penetrates a foundation or exterior wall below grade must be sleeved and protected from corrosion and from stress caused by settlement, with the annular space sealed to prevent gas or water entry. Casting pipe directly into concrete invites corrosion and shear, joints and unions may not be concealed inside the wall, and PE is not permitted to enter a building.

Trích dẫn luật: IFGC §404

Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với Journeyman Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra
Báo lỗi