AdministrationCâu 91 / 110

The adopted plumbing code and a manufacturer's installation instructions differ on the maximum length of a listed flexible water connector. Which controls, and what is the guiding principle?

a.The code always wins even for listed products
b.Ignore both and use judgment
c.The more restrictive requirement governs; listed products must be installed per their listing where the code defers to it
d.The instructions always win over any code

Giải thích

When a listed product's instructions and the code both apply, the more restrictive requirement governs, and the code generally requires listed products to be installed in accordance with their listing where it defers to the manufacturer. This protects the listing's validity while still meeting minimum code. The plumber documents which requirement was applied.

Trích dẫn luật: UPC §101.0

Luyện miễn phí toàn bộ 110 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với Master Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra