安全第 1238 / 1632 题

Which of the following is a required element of a compliant IIPP under Title 8 §3203?

a.A written emergency action plan under section 3220 of Title 8
b.An annual third-party audit of the program
c.A system for identifying and evaluating workplace hazards
d.A copy of the program approved by Cal/OSHA

解析

Section 3203(a)(4) lists procedures for identifying and evaluating workplace hazards, including scheduled periodic inspections, as a required element. The others are real documents attached to the wrong standard: an emergency action plan is section 3220 and is required only of employers the standards specifically cover, not of every employer as part of the IIPP; nothing in section 3203 calls for an outside audit, annual or otherwise, and the inspections the standard does require are the employer's own; and the Division never approves or certifies an IIPP in advance - it reads the program during an inspection and cites what is missing.

法律依据: 8 CCR §3203(a)(4); §3220; §3395(i)