When a small appliance's compressor is operable, why does the rule require a higher recovery level (90%) than when it is inoperable (80%)?

a.Because operable compressors always hold less oil
b.Because a working compressor can pump refrigerant out, making higher recovery achievable
c.Because HFCs recover faster than CFCs
d.Because the appliance must be recharged afterward

解析

A working compressor actively pumps refrigerant toward the recovery equipment, so more of the charge can realistically be removed, and the rule sets the higher 90% target. When the compressor cannot run, recovery is harder, so the standard is 80%. The rule scales the requirement to what is practically achievable.

法律依据: 40 CFR §82.156

免费刷完整 240 道题库 — 无需注册。